نام تجاری:
Honeywell
شماره مدل:
سری 2CCP
| FEATURES | BENEFITS | 
|---|---|
| Dual direction | Covers cable spans up to 656 ft*. Fewer number of switches required per installation creates savings on unit and wiring costs | 
| Configurable platform | Many options available within one package size. 576 possible SKU combinations. Options for conduit ports, contacts, actuation direction, LED, E-stop, and restart button | 
| Direct-opening, snap-action contacts | Contacts are held closed when the actuating cable is under proper tension and the reset knob is set to the run position. Upon activation, a cam positively open the NC contacts. The snap-action operation causes the mechanical latch almost immediately | 
| Latches on both slackened and pulled cable | Provides tension loss monitoring due to wire breakage or thermal expansion | 
| Wide tolerance zone for cable tensioning | Protects against nuisance tripping and the effects of thermal expansion. ±30°F for cable runs up to 500 ft. Longer runs achievable at smaller temperature windows | 
| Integral reset mechanism | NC switch contacts remain open until the unit is reset by properly tensioning the cable and manually rotating the blue reset knob to "Run" condition following switch actuation | 
| Restart button | Equipment is not allowed to restart automatically after the cable-pull switch is reset. The integrated restart button can be used to send a signal back to the PLC for equipment start. This is in lieu of installing a local control station or using an existing HMI | 
| Improved LED | More light intensity and better side viewing ensures switch status can be seen easily from a distance. Available in 24 Vdc, 120 Vac, or 240 Vac | 
| E-stop button | Provides E-stop access even at the extreme ends of the span | 
| Replaceable front cover | Units with an E-stop are prone to damage. Impact-resistant plastic cover has been designed for fast and economic replacement. LED and restart button are mounted to base of unit and do not require replacement or rewiring | 
| Improved tension window | Magnified window and clear markings makes system setup and rope tension maintenance faster and more precise | 
| External mounting holes | Front cover does not need to be removed to access mounting holes creating easier installation and maintenance access | 
| Large wiring cavity with straight through wiring | Easier access to contact block allows for faster and simpler wiring | 
| Optional rear conduit port | Option to route wiring through the back of the unit for easier installation and to eliminate looping cable | 
| DESIGNATION AND UTILIZATION CATEGORY | RATED OPERATIONAL CURRENT IE (A) AT RATED OPERATIONAL VOLTAGE (V) | ||
|---|---|---|---|
| 24 V | 120 V | 240 V | |
| AC15 (Contact Rating) | A300 | - | 6 A | 
| DC13 (Contact Rating) | Q300 | 2.8 A | 0.55 A | 
 
 
 